HVAC & refrigeration · Product reference

Danfoss ICLX 40 027H4040 Solenoid Valve

Danfoss ICLX 40 027H4040 Solenoid Valve. Confirmed details: Connection type: Butt weld, EN 10220. Confirm medium, working pressure, temperature and end connections before ordering.

Brand
Danfoss
Product type
Solenoid Valve
Model number
ICLX 40
Part number
027H4040

Request pricing & availability

Share your quantity and delivery destination. We’ll confirm the configuration, availability and lead time in your quotation.

Need help identifying a part?
Include a nameplate photo or datasheet with your inquiry so we can check the exact reference.

At a glance

Product overview

Danfoss ICLX 40 027H4040 Solenoid Valve is documented by Danfoss. The confirmed specification subset includes Connection type: Butt weld, EN 10220.

For selection, compare medium, working pressure, temperature and end connections with the installed equipment. A similar model code does not establish interchangeability.

Key features

  • Catalog classification: Solenoid Valve
  • Identification reference: ICLX 40
  • Connection type: Butt weld, EN 10220

Technical reference

Technical specifications

Specifications for Danfoss ICLX 40 027H4040 Solenoid Valve
Volume8.68 Liter
UL markYes
ApprovalEAC TÜV UA UL
DirectionStraightway
Net weight6.333 Kilogram
Description2-step solenoid valve
Gross weight9.542 Kilogram
Product TypeICLX 40
Product name2-step solenoid valve
RefrigerantsR1234yf R1234ze(E) R125 R134a R152a R170 R22 R227ea R236fa R245fa R290 R32 R401A R402A R404A R407A R407B R407C R407F R407H R409A R410A R413A R417A R421A R422A R422B R422D R438A R442A R444B R447A R447B R448A R449A R449B R450A R452A R452B R452C R454A R454B R454C R455A R463A R502 R507A R512A R513A R513B R515A R515B R516A R600 R600a R717 R744
Body materialSteel
Valve versionStandard version
Actuator system2 EVM pilot sol valve module
Surface coatingZn (TLP)
Valve operationSolenoid operated
Kv value [m³/h]29.000 m³/h
Manufacturer code027H4040
Cv value [gal/min]33.640 gal/min
Connection materialSteel
Connection standardEN 10220
Product descriptionSolenoid valve
Material DescriptionICLX 40 DIN
Inlet connection typeButt weld
Opening configuration1-step (optional setting) 2-step (default)
Step 2 initializationDelta p < 1.25 bar (18 psig)
Outlet connection typeButt weld
Manual operation optionManual open spindle
Flow direction indicatorEmbossed 1-way arrow
Inlet connection size [in]1 1/2 in
Inlet connection size [mm]40.00 mm
Max. Working Pressure [bar]65.0 bar
Outlet connection size [in]1 1/2 in
Outlet connection size [mm]40.0 mm
Max. Working Pressure [psig]943 psig
Ext pilot pressure connectionWeld nipple (P2 Port)
Step 1 opening degree (~) [%]10 %
Temperature range [°C] [max]120 °C
Temperature range [°C] [min]-60 °C
Temperature range [°F] [max]248 °F
Temperature range [°F] [min]-76 °F

Check the exact variant and operating limits against the applicable manufacturer documentation. View the recorded source.

Selection context

Applications

  • Fluid-control system maintenance; confirm the exact configuration before use.
  • Replacement-part evaluation against the original equipment documentation.

Confirm compatibility with your equipment and operating conditions before selecting a replacement.

Traceable information

Documents & sources

Product information source

Source
Danfoss
Source type
Manufacturer source
Source last checked
View source (opens in a new tab)

This reference identifies the recorded information source. It does not establish authorized distributor status or certify the condition or origin of an individual supplied item.

Before you order

Ordering information

Model
ICLX 40
Quantity
Specify the required quantity in the inquiry.
Lead time
To be confirmed for the selected configuration and destination.
Product reference
Danfoss ICLX 40 027H4040
Price and availability
Subject to quotation; confirm before placing an order.
Configuration to confirm
Medium, working pressure, temperature and end connections
Manufacturer part number
027H4040

Identify the part

Send the complete model, part number and any required suffix or configuration.

Share your requirements

Include quantity, destination, target delivery date and required documents.

Confirm the quotation

Review availability, condition, origin, lead time and commercial terms before ordering.

Product questions

Frequently asked questions

How should I identify Danfoss ICLX 40 027H4040?

Use the reference Danfoss ICLX 40 027H4040 together with a clear nameplate photo and the complete equipment model. Confirm any suffixes before ordering.

Which specifications should be checked before ordering?

Check medium, working pressure, temperature and end connections. Only the specification items shown with the linked official source were confirmed in this review; do not assume other configurations share the same ratings.

Can a similar model be used as a replacement?

Do not select a replacement by a similar name alone. Compare the full code, interfaces, operating limits and equipment requirements with the manufacturer documentation.

What information is needed for a quotation?

Provide Danfoss ICLX 40 027H4040, quantity, destination and required delivery date. Include photos or an existing datasheet if the configuration is uncertain.

Are price, stock and lead time confirmed on this page?

No. Request a current quotation for the exact configuration. Availability, lead time and applicable warranty terms must be agreed before ordering.