Product overview

Danfoss KP2 060-112091 Pressure Switch, -0.2~+5bar, Auto Reset, 1/4" Flare, Made in India is listed as a pressure switch for sourcing and identification. Exact technical ratings and manufacturer identity must be checked against the nameplate and official documentation before ordering.

For selection, compare complete model, dimensions, interfaces and operating requirements with the installed equipment. A similar model code does not establish interchangeability.

Key features

  • Catalog classification: Pressure Switch
  • Identification reference: KP2
  • Exact configuration and ratings must be confirmed before selection.

Technical reference

Technical specifications

Specifications for Danfoss KP2 060-112091 Pressure Switch, -0.2~+5bar, Auto Reset, 1/4" Flare, Made in India
Volume0.57 Liter
CE markYes
UL markYes
ApprovalBV CCC CE DNV GL LR LVD PED RINA RMRS RoHS China UA c UL us UL353, CS C22.2 c UL us UL873, CS C22.2
Net weight0.297 Kilogram
Gross weight0.332 Kilogram
Product TypeKP2
Product namePressure switch
RefrigerantsR113 R1233zd(E) R1234yf R1234yz R1234ze(E) R124 R134a R22 R404A R407A R407C R407F R407H R422B R422D R438A R448A R449A R449B R450A R452A R454C R455A R507A R513A R515B
Contact ratingAC15=10 A, 400 V AC1=16 A, 400 V AC3=16 A, 400 V DC13=12 W, 220 V LR=112 A, 400 V
Reset functionAuto
Amb. Temp. Note80 °C/176 °F for max 120 min
Application noteNot applicable for liquid line
Contact functionSPDT
Regulation range6 inHg - 73 psig
Manufacturer code060-112091
Enclosure rating IPIP44
Product descriptionPressure Switch
Material DescriptionKP2 Pressure Switch M/36
Pressure Male/FemaleMale
Electrical connectionRubber cable gland
Oil free refrigerantsR134a R513A R515B
Differential [bar] [max]1.50 bar
Differential [bar] [min]0.40 bar
Differential [psi] [max]22.00 psi
Differential [psi] [min]6.00 psi
Lubricants compatibilityOilfree applications
Pressure connection size1/4
Pressure connection typeFlare
Pressure sensing elementBellows
UL approved refrigerantsR113 R124 R134a R22 R404A R407A R407C R407F R407H R422B R422D R438A R448A R449A R449B R450A R452A R507A R513A R515B
Enclosure rating Nema (~)2
Max. test pressure [psig]290.0 psig
EN 60947 wiring propertiesFlex, ferrules: 0.5-1.5 mm2 Flex, no ferrules: 0.7-2.5 mm2 Solid/stranded: 0.75-2.5 mm2
Electrical connection size6-14 mm
Max. Working Pressure [bar]17.0 bar
Max. test pressure [bar] Pe20.0 bar
Max. Working Pressure [psig]245 psig
Pressure connection standardDIN 8906
EN 60947 electrical propertiesInsulation: 400V Pollution degree: 3 Rated impulse voltage: 4 kV Short circuit prot, fuse: 16A
Regulation range [bar] Pe [max]5.00 bar
Regulation range [bar] Pe [min]-0.20 bar
Ambient temperature range [°C] [max]65 °C
Ambient temperature range [°C] [min]-25 °C
Ambient temperature range [°F] [max]149 °F
Ambient temperature range [°F] [min]-13 °F

Check the exact variant and operating limits against the applicable manufacturer documentation.

Selection context

Applications

  • Equipment maintenance and procurement; confirm the exact configuration before use.
  • Replacement-part evaluation against the original equipment documentation.

Confirm compatibility with your equipment and operating conditions before selecting a replacement.

Before you order

Ordering information

Model
KP2
Quantity
Specify the required quantity in the inquiry.
Lead time
To be confirmed for the selected configuration and destination.
Product reference
Danfoss KP2 060-112091
Price and availability
Subject to quotation; confirm before placing an order.
Configuration to confirm
Complete model, dimensions, interfaces and operating requirements
Manufacturer part number
060-112091

Identify the part

Send the complete model, part number and any required suffix or configuration.

Share your requirements

Include quantity, destination, target delivery date and required documents.

Confirm the quotation

Review availability, condition, origin, lead time and commercial terms before ordering.

Product questions

Frequently asked questions

How should I identify Danfoss KP2 060-112091?

Use the reference Danfoss KP2 060-112091 together with a clear nameplate photo and the complete equipment model. Confirm any suffixes before ordering.

Which specifications should be checked before ordering?

Check complete model, dimensions, interfaces and operating requirements. No model-specific numerical ratings have been independently confirmed from official documentation for this listing.

Can a similar model be used as a replacement?

Do not select a replacement by a similar name alone. Compare the full code, interfaces, operating limits and equipment requirements with the manufacturer documentation.

What information is needed for a quotation?

Provide Danfoss KP2 060-112091, quantity, destination and required delivery date. Include photos or an existing datasheet if the configuration is uncertain.

Are price, stock and lead time confirmed on this page?

No. Request a current quotation for the exact configuration. Availability, lead time and applicable warranty terms must be agreed before ordering.