HVAC & refrigeration · Product reference

Elitech HLD-200+ Leak Detector

Compact corona-type refrigerant leak detector with seven sensitivity levels, 3 g/year limiting sensitivity, automatic calibration, LED leak indication and audible alarms.

Brand
Elitech
Product type
Leak Detector
Model number
HLD-200+

Request pricing & availability

Share your quantity and delivery destination. We’ll confirm the configuration, availability and lead time in your quotation.

Need help identifying a part?
Include a nameplate photo or datasheet with your inquiry so we can check the exact reference.

At a glance

Product overview

The Elitech HLD-200+ is a compact portable halogen refrigerant leak detector with a reliable negative-corona sensor and upgraded low-power circuitry. Microcomputer-controlled operation and automatic startup calibration use the ambient refrigerant concentration as the zero reference.

Seven adjustable sensitivity levels, progressive LED leakage indication, audible alarms and a three-color battery-voltage indicator support refrigeration servicing. The official page lists limiting sensitivity of 3 g/year (0.11 oz/year in the introduction), approximately 6 seconds of warm-up and a 2-second reset. It operates at 0–52°C on 3 V DC from two AA batteries. Dimensions are 44 × 61 × 176 mm, probe length is 30.5 cm and weight is 185 g.

The introductory text states response within 3 seconds, while the technical parameter image says instantaneous. Confirm the response specification for the supplied version. The manufacturer states compliance with EN14624, SAE J1627 and RoHS.

Key features

  • Negative-corona refrigerant sensor with low-power upgraded circuitry.
  • Seven sensitivity settings and limiting sensitivity of 3 g/year.
  • Automatic startup calibration with ambient refrigerant concentration used as the zero point.
  • Progressive LED leakage display, audible alarm and three-color battery-voltage indication.
  • Replaceable sensor, protective sleeve and compact portable body.
  • Approximately 6-second warm-up and 2-second reset; continuous detection.
  • 30.5 cm probe; 185 g weight; 44 × 61 × 176 mm body.

Technical reference

Technical specifications

Specifications for Elitech HLD-200+ Leak Detector
weight185g
reset_time2 seconds
power_supply3V DC, 2 AA high-energy batteries
probe_length30.5cm
warm_up_timeApprox. 6 seconds
response_timeInstant
rohs_compliantYes
detection_methodContinuous, unlimited
limit_sensitivity3gr/yr
overall_dimension44*61*176mm
compliance_standardSAE_J1627, EN14624
operating_temperature0 ~ 52℃

Check the exact variant and operating limits against the applicable manufacturer documentation. View the recorded source.

Selection context

Applications

  • Leak checks on refrigeration and air-conditioning systems.
  • HVAC service work involving R11, R22, R134a, R404A and R410A.
  • Detection of halogenated refrigerants including CFCs, HCFCs, HFCs and blends listed by the manufacturer.

Confirm compatibility with your equipment and operating conditions before selecting a replacement.

Traceable information

Documents & sources

Product information source

Source
Elitech
Source type
Manufacturer source
Source last checked
View source (opens in a new tab)

This reference identifies the recorded information source. It does not establish authorized distributor status or certify the condition or origin of an individual supplied item.

Before you order

Ordering information

Brand
Elitech
Model
HLD-200+
Dimensions
44 × 61 × 176 mm; probe 30.5 cm; weight 185 g.
Power supply
3 V DC from two AA batteries; introductory text describes batteries as included.
Quotation details
Specify exact model, quantity, refrigerant and destination. Confirm package contents, price, stock and lead time.
Specification confirmation
Confirm response specification: introduction states within 3 seconds; technical parameter image states instantaneous.

Identify the part

Send the complete model, part number and any required suffix or configuration.

Share your requirements

Include quantity, destination, target delivery date and required documents.

Confirm the quotation

Review availability, condition, origin, lead time and commercial terms before ordering.

Product questions

Frequently asked questions

How should I identify Elitech HLD-200+?

Use the reference Elitech HLD-200+ together with a clear nameplate photo and the complete equipment model. Confirm any suffixes before ordering.

Which specifications should be checked before ordering?

Check target gas, sensing technology and detection sensitivity. Only the specification items shown with the linked official source were confirmed in this review; do not assume other configurations share the same ratings.

Can a similar model be used as a replacement?

Do not select a replacement by a similar name alone. Compare the full code, interfaces, operating limits and equipment requirements with the manufacturer documentation.

What information is needed for a quotation?

Provide Elitech HLD-200+, quantity, destination and required delivery date. Include photos or an existing datasheet if the configuration is uncertain.

Are price, stock and lead time confirmed on this page?

No. Request a current quotation for the exact configuration. Availability, lead time and applicable warranty terms must be agreed before ordering.