Match the complete model and part number to your equipment before ordering.
HVAC & refrigeration · Product reference
Elitech HLD-200+ Leak Detector
Compact corona-type refrigerant leak detector with seven sensitivity levels, 3 g/year limiting sensitivity, automatic calibration, LED leak indication and audible alarms.
- Brand
- Elitech
- Product type
- Leak Detector
- Model number
- HLD-200+
Request pricing & availability
Share your quantity and delivery destination. We’ll confirm the configuration, availability and lead time in your quotation.
Need help identifying a part?
Include a nameplate photo or datasheet with your inquiry so we can check the exact reference.
At a glance
Product overview
The Elitech HLD-200+ is a compact portable halogen refrigerant leak detector with a reliable negative-corona sensor and upgraded low-power circuitry. Microcomputer-controlled operation and automatic startup calibration use the ambient refrigerant concentration as the zero reference.
Seven adjustable sensitivity levels, progressive LED leakage indication, audible alarms and a three-color battery-voltage indicator support refrigeration servicing. The official page lists limiting sensitivity of 3 g/year (0.11 oz/year in the introduction), approximately 6 seconds of warm-up and a 2-second reset. It operates at 0–52°C on 3 V DC from two AA batteries. Dimensions are 44 × 61 × 176 mm, probe length is 30.5 cm and weight is 185 g.
The introductory text states response within 3 seconds, while the technical parameter image says instantaneous. Confirm the response specification for the supplied version. The manufacturer states compliance with EN14624, SAE J1627 and RoHS.
Key features
- Negative-corona refrigerant sensor with low-power upgraded circuitry.
- Seven sensitivity settings and limiting sensitivity of 3 g/year.
- Automatic startup calibration with ambient refrigerant concentration used as the zero point.
- Progressive LED leakage display, audible alarm and three-color battery-voltage indication.
- Replaceable sensor, protective sleeve and compact portable body.
- Approximately 6-second warm-up and 2-second reset; continuous detection.
- 30.5 cm probe; 185 g weight; 44 × 61 × 176 mm body.
Technical reference
Technical specifications
| weight | 185g |
|---|---|
| reset_time | 2 seconds |
| power_supply | 3V DC, 2 AA high-energy batteries |
| probe_length | 30.5cm |
| warm_up_time | Approx. 6 seconds |
| response_time | Instant |
| rohs_compliant | Yes |
| detection_method | Continuous, unlimited |
| limit_sensitivity | 3gr/yr |
| overall_dimension | 44*61*176mm |
| compliance_standard | SAE_J1627, EN14624 |
| operating_temperature | 0 ~ 52℃ |
Check the exact variant and operating limits against the applicable manufacturer documentation. View the recorded source.
Selection context
Applications
- Leak checks on refrigeration and air-conditioning systems.
- HVAC service work involving R11, R22, R134a, R404A and R410A.
- Detection of halogenated refrigerants including CFCs, HCFCs, HFCs and blends listed by the manufacturer.
Confirm compatibility with your equipment and operating conditions before selecting a replacement.
Traceable information
Documents & sources
Product information source
- Source
- Elitech
- Source type
- Manufacturer source
- Source last checked
This reference identifies the recorded information source. It does not establish authorized distributor status or certify the condition or origin of an individual supplied item.
Before you order
Ordering information
- Brand
- Elitech
- Model
- HLD-200+
- Dimensions
- 44 × 61 × 176 mm; probe 30.5 cm; weight 185 g.
- Power supply
- 3 V DC from two AA batteries; introductory text describes batteries as included.
- Quotation details
- Specify exact model, quantity, refrigerant and destination. Confirm package contents, price, stock and lead time.
- Specification confirmation
- Confirm response specification: introduction states within 3 seconds; technical parameter image states instantaneous.
Identify the part
Send the complete model, part number and any required suffix or configuration.
Share your requirements
Include quantity, destination, target delivery date and required documents.
Confirm the quotation
Review availability, condition, origin, lead time and commercial terms before ordering.
Product questions
Frequently asked questions
How should I identify Elitech HLD-200+?
Use the reference Elitech HLD-200+ together with a clear nameplate photo and the complete equipment model. Confirm any suffixes before ordering.
Which specifications should be checked before ordering?
Check target gas, sensing technology and detection sensitivity. Only the specification items shown with the linked official source were confirmed in this review; do not assume other configurations share the same ratings.
Can a similar model be used as a replacement?
Do not select a replacement by a similar name alone. Compare the full code, interfaces, operating limits and equipment requirements with the manufacturer documentation.
What information is needed for a quotation?
Provide Elitech HLD-200+, quantity, destination and required delivery date. Include photos or an existing datasheet if the configuration is uncertain.
Are price, stock and lead time confirmed on this page?
No. Request a current quotation for the exact configuration. Availability, lead time and applicable warranty terms must be agreed before ordering.