HVAC & refrigeration · Product reference

Elitech ILD-200 Leak Detector

Handheld NDIR refrigerant leak detector with three sensitivity settings, a 2.8-inch TFT display, peak indication, audible and visual alarms, and rechargeable battery power.

Brand
Elitech
Product type
Leak Detector
Model number
ILD-200

Request pricing & availability

Share your quantity and delivery destination. We’ll confirm the configuration, availability and lead time in your quotation.

Need help identifying a part?
Include a nameplate photo or datasheet with your inquiry so we can check the exact reference.

At a glance

Product overview

The Elitech ILD-200 is a handheld refrigerant leak detector using non-dispersive infrared (NDIR) gas sensing. It measures absorption of infrared light by refrigerant gas to help locate leaks. The manufacturer describes improved resistance to interference and sensor poisoning compared with conventional detection methods.

Three selectable sensitivity levels, a 2.8-inch TFT color display, peak recording, audible and visual alarms, mute control and a flexible probe support service work. The display shows battery level, buzzer status, leakage indication, peak level, sensor faults, warm-up countdown and sensitivity. The official page states a 30-second warm-up, up to eight hours of use per charge, sensor life up to ten years and dimensions of 201 × 86 × 38 mm.

Published sensitivity claims differ: the introduction states 0.14 oz/year, body text states 2 g/year and the comparison image states 3 g/year. The comparison image lists response below one second. Confirm the sensitivity and response specifications for the supplied version.

Key features

  • Non-dispersive infrared refrigerant sensing with resistance to interference and poisoning as described by the manufacturer.
  • Three sensitivity settings: low, medium and high.
  • 2.8-inch TFT display with current leakage indication and peak recording.
  • Audible and visual alarms, selectable mute mode, reset and sensor-fault indication.
  • Approximately 30-second warm-up and up to eight hours of operation per charge.
  • Flexible probe, rechargeable lithium battery and compact 201 × 86 × 38 mm body.
  • Manufacturer-stated sensor service life up to ten years; comparison image states response below one second.

Technical reference

Technical specifications

Specifications for Elitech ILD-200 Leak Detector
sensitivity7 levels
sensor_typeSemiconductor sensor
power_supplyRechargeable
warm-up_time30s
product_modelLD-200
probe_materialFlexible stainless steel
display_interfaceHigh-brightness digital tube
operating_temperature0℃ ~ 50℃
minimum_detectable_leak_rate3 grams per year

Check the exact variant and operating limits against the applicable manufacturer documentation. View the recorded source.

Selection context

Applications

  • Leak detection in air-conditioning systems, refrigerators, freezers, cold rooms and larger refrigeration systems.
  • Automotive air-conditioning refrigerant leak checks.
  • Detection of manufacturer-listed CFC, HCFC, HFC and HFO refrigerants, including R32 and R1234yf; confirm compatibility with the exact refrigerant.

Confirm compatibility with your equipment and operating conditions before selecting a replacement.

Traceable information

Documents & sources

Product information source

Source
Elitech
Source type
Manufacturer source
Source last checked
View source (opens in a new tab)

This reference identifies the recorded information source. It does not establish authorized distributor status or certify the condition or origin of an individual supplied item.

Before you order

Ordering information

Brand
Elitech
Model
ILD-200
Power supply
Rechargeable lithium battery; stated runtime up to eight hours per charge.
Quotation details
Specify exact model, refrigerant, quantity and destination. Confirm accessories, price, availability and lead time.
Detection principle
Non-dispersive infrared (NDIR)
Specification confirmation
The source states 0.14 oz/year, 2 g/year and 3 g/year in different sections. Confirm sensitivity and response for the supplied version.

Identify the part

Send the complete model, part number and any required suffix or configuration.

Share your requirements

Include quantity, destination, target delivery date and required documents.

Confirm the quotation

Review availability, condition, origin, lead time and commercial terms before ordering.

Product questions

Frequently asked questions

How should I identify Elitech ILD-200?

Use the reference Elitech ILD-200 together with a clear nameplate photo and the complete equipment model. Confirm any suffixes before ordering.

Which specifications should be checked before ordering?

Check target gas, sensing technology and detection sensitivity. Only the specification items shown with the linked official source were confirmed in this review; do not assume other configurations share the same ratings.

Can a similar model be used as a replacement?

Do not select a replacement by a similar name alone. Compare the full code, interfaces, operating limits and equipment requirements with the manufacturer documentation.

What information is needed for a quotation?

Provide Elitech ILD-200, quantity, destination and required delivery date. Include photos or an existing datasheet if the configuration is uncertain.

Are price, stock and lead time confirmed on this page?

No. Request a current quotation for the exact configuration. Availability, lead time and applicable warranty terms must be agreed before ordering.