HVAC & refrigeration · Product reference

Danfoss AKS 21W 084N2017 Temperature Sensor

Danfoss AKS 21W 084N2017 Temperature Sensor. Confirmed details: Electrical connection: Cable. Confirm measurement range, output signal, supply voltage and process connection before ordering.

Brand
Danfoss
Product type
Temperature Sensor
Model number
AKS 21W
Part number
084N2017

Request pricing & availability

Share your quantity and delivery destination. We’ll confirm the configuration, availability and lead time in your quotation.

Need help identifying a part?
Include a nameplate photo or datasheet with your inquiry so we can check the exact reference.

At a glance

Product overview

Danfoss AKS 21W 084N2017 Temperature Sensor is documented by Danfoss. The confirmed specification subset includes Electrical connection: Cable.

For selection, compare measurement range, output signal, supply voltage and process connection with the installed equipment. A similar model code does not establish interchangeability.

Key features

  • Catalog classification: Temperature Sensor
  • Identification reference: AKS 21W
  • Electrical connection: Cable

Technical reference

Technical specifications

Specifications for Danfoss AKS 21W 084N2017 Temperature Sensor
Volume0.522 Liter
CE markYes
ApprovalCE
Cable typeSilicone
Net weight0.261 Kilogram
Wires [pcs]2 pc
EEE category5 small equipment (any external dimension < 50 cm)
Gross weight0.294 Kilogram
Product TypeAKS 21 M
Product nameTemperature sensor
Sensor InsertExchangeable
Connection typeWeld
Cable length [m]2.500 m
In scope of WEEEYes
Cable length [in]98.43 in
Manufacturer code084N2017
CoolselectorFilterActive models
Enclosure rating IPIP56
Sensor element [pc]1 pc
Sensor element typePt
Material DescriptionSensor AKS 21 M 2.5m
Electrical connectionCable
Process connection size22
Process connection typeØ
Sensor element standardEN 60751
Process connection notesWeldable
Protection tube materialSTAINLEES STEEL
Sensor element toleranceClass B
Electrical connection size2 wire
Measuring range [°C] [max]200 °C
Measuring range [°C] [min]-60 °C
Measuring range [°F] [max]392 °F
Measuring range [°F] [min]-76 °F
Protection tube length [in]1.97 in
Protection tube length [mm]50.0 mm
Protection tube diameter [in]0.280 in
Protection tube diameter [mm]7.0 mm
Sensor elem. resistance [Ohm]1000 Ohm
Ambient temperature max. [°C]180 °C
Ambient temperature max. [°F]356 °F
Cable tempr. range [°C] [max]200 °C
Cable tempr. range [°C] [min]-60 °C

Check the exact variant and operating limits against the applicable manufacturer documentation. View the recorded source.

Selection context

Applications

  • Instrumentation and equipment monitoring; confirm the exact configuration before use.
  • Replacement-part evaluation against the original equipment documentation.

Confirm compatibility with your equipment and operating conditions before selecting a replacement.

Traceable information

Documents & sources

Product information source

Source
Danfoss
Source type
Manufacturer source
Source last checked
View source (opens in a new tab)

This reference identifies the recorded information source. It does not establish authorized distributor status or certify the condition or origin of an individual supplied item.

Before you order

Ordering information

Model
AKS 21W
Quantity
Specify the required quantity in the inquiry.
Lead time
To be confirmed for the selected configuration and destination.
Product reference
Danfoss AKS 21W 084N2017
Price and availability
Subject to quotation; confirm before placing an order.
Configuration to confirm
Measurement range, output signal, supply voltage and process connection
Manufacturer part number
084N2017

Identify the part

Send the complete model, part number and any required suffix or configuration.

Share your requirements

Include quantity, destination, target delivery date and required documents.

Confirm the quotation

Review availability, condition, origin, lead time and commercial terms before ordering.

Product questions

Frequently asked questions

How should I identify Danfoss AKS 21W 084N2017?

Use the reference Danfoss AKS 21W 084N2017 together with a clear nameplate photo and the complete equipment model. Confirm any suffixes before ordering.

Which specifications should be checked before ordering?

Check measurement range, output signal, supply voltage and process connection. Only the specification items shown with the linked official source were confirmed in this review; do not assume other configurations share the same ratings.

Can a similar model be used as a replacement?

Do not select a replacement by a similar name alone. Compare the full code, interfaces, operating limits and equipment requirements with the manufacturer documentation.

What information is needed for a quotation?

Provide Danfoss AKS 21W 084N2017, quantity, destination and required delivery date. Include photos or an existing datasheet if the configuration is uncertain.

Are price, stock and lead time confirmed on this page?

No. Request a current quotation for the exact configuration. Availability, lead time and applicable warranty terms must be agreed before ordering.